TOMIZAWA TETSUYA
   Department   Undergraduate School  , School of Science and Technology
   Position   Associate Professor
Date 2009/11
Presentation Theme Construction of Civil Building Using Three Dimensional Seismic Isolation System (Part 2, Tests for Three Dimension Seismic Isolation System)
Conference The 13th Asia Pacific Vibration Conference
Conference Type International
Presentation Type Speech (General)
Contribution Type Collaborative
Country New Zealand
Venue University of Canterbury, Christchurch
Holding period 2009/11/22~2009/11/25
Publisher and common publisher Junji Suhara, Ryoichiro Matsumoto, Shuhei Okamoto, Yoichi Himeno, Itaru Kurosawa, Takuya Nishimura, Yoshiro Kai, Yasuo Tsuyuki, Toshiaki Kamei, Takafumi Fujita, Osamu Takahashi, Hideaki Hasegawa, Tetsuya Tomizawa, Hiromasa Aida
Details The three dimensional (3D) seismic base isolation system for applying to the civil
building have been proposed in Part 1. In this paper, test results for confirming
mechanical property of the device are reported. The proposed 3D seismic isolation
system consists of the 3D seismic isolation device and the rocking suppression
device. The 3D seismic isolation device consists of laminated rubber bearings as
horizontal isolation devices and air springs as vertical isolation devices. The
rocking suppression device consist of oil dampers connected by oil pressure piping
in order to control a rocking vibration which becomes easy to be excited because
the vertical rigidity of seismic device lowers. To confirm the applicability to a real
building to each device, the tests with actual size devices were executed. As the
results, the seismic isolation performance of 3D isolation device was confirmed,
and the rocking control performance of the rocking suppression device was
confirmed.